Tests Conducted using a Standard 1" Dynamic
Electronic Air Cleaner
All results
posted are from independent testing laboratories
|
Test Results # 1
|
| Room Size |
11,000 cu.ft. (311.5 cu.M) |
| Air Flow Rate |
400 CFM (0.19 M3/second) |
| Particle Size Measured |
0.3 - 0.5 Microns |
| Filter Used for Test |
Dynamics standard 1" electronic furnace
panel
12" x 24" x 1" (305mm x 610mm x 25.4mm) |
| Decrease in Particle Count in One Hour: |
80% |
| Decrease in Particle Count in Two Hours: |
97.2% |
|
Test Results # 2
|
|
Test House Size |
Estimated at 10,000 cu. ft. (283 cu. M) |
| Air Flow Rate |
Standard Domestic Central Heater
Air flow rate estimated at 1200 CFM (0.566 M3/second) |
| Filter Used for Test |
Dynamic standard 1" electronic furnace panel
20" x 20" x 1" (508mm x 508mm x 25.4mm) |
| Particle Size (Microns) |
0.3 - 0.5 |
0.5 - 1.0 |
1.0 - 5.0 |
7.5 |
| Initial Count |
700,000 |
425,000 |
100,000 |
9,000 |
Count After Stabilization
(Approximately 10 Hours) |
18,000 |
6,000 |
<1,000 |
<1,000 |
| Percent Reduction |
97% |
98.6 |
99% |
99% |
|
Test Results # 3
|
| Chamber Size |
7 cu. ft. (.20 cu. M) |
| Air Flow Rate |
300 CFM (0.14 M3/second) |
| Particle Size Measured |
0.3 Microns |
| Filter Used for Test |
Dynamic standard 1" electronic furnace panel
12" x 24" x 1" (305mm x 610mm x 25.4mm) |
Decrease in 0.3 Micron Particles
in One Minute |
80% (Average of Three Tests)
at 46% Relative Humidity
82% (Average of Three Tests)
at 59% Relative Humidity |
|
Test Results # 4 - Comparison
to 99.95% HEPA Filter
|
| Room Size |
260 cu.ft. (7.36 cu.M) |
| Air Flow Rate |
300 CFM (0.14 M3/second) |
| Filter Used for Test |
Dynamic standard 1" electronic furnace panel
12" x 24" x 1" (305mm x 610mm x 25.4mm) |
| HEPA Filter Removed |
94% of 0.3 Micron Size Particles in 15
minutes |
| DYNAMIC Filter Removed |
89% of 0.3 Micron Size Particles in 15
minutes |